Add Heater

In some cases, the temperature in the aquarium might go beyond the optimal range for our coral and fish residents, particularly in winter. Therefore, it is advisable to incorporate a heater to aid in maintaining the warmth of the tank.

Here is what you’ll need to get started:

  • A heater is connected to a controllable outlet.
    TIP: It is highly recommended to use a heater that has an integrated thermostat. By setting the thermostat to turn off at a temperature slightly higher than what you want for the tank, you can ensure that the heater will maintain the desired temperature even if the controller loses connection with the outlet. This redundancy will keep your tank inhabitants safe.

  • Temperature probe available in our system. You can use the same probe to monitor the tank’s water temperature.
    TIP: If you still need to add the Temperature Sensor as an INPUT, please follow the instructions here.

Step 1: Create the Heater Output

  1. From the STATUS screen on your HYDROS app, top on the three horizontal dots to the right of the OUTPUTS label and select “Add New Output.”
  2. Tap on the + symbol at the bottom right of the page
  3. Type in the name of your new output and then tap “Create.”

Step 2: Configure your Heater

  • Type: Select “Heater”
  • ON Temperature: This option allows you to select the highest point before the Control turns ON your Heater.
  • OFF Temperature: This option allows you to select the lowest point before the Control turns OFF your Heater
  • Temperature Input #1: Select the first temperature sensor input. 
    TIP: To see a list of all inputs available on MULTIPLE devices, you must first create a Collective. Otherwise, only inputs on the same device will show.
    WARNING: This input is required. If you leave this field blank, the output will automatically go into the “Fallback” state.
  • Temperature Input #2: Select the second temperature sensor input. 
    TIP: HYDROS will use the sensor with the highest temperature regardless of the input number.
    WARNING: If the temperature difference between the two inputs is more than 1C (1.8F), it will trigger an alarm.
  • Output Device: Here, you select the location of your heater
  • If Input/Depends On Unavailable: It allows you to specify what the output will do should an input or output it depends on become unavailable.
    WARNING: If using a WiFi strip or WiFi outlet, this is NOT a “fallback” stat. If you are using an XP8 or a Drive Port, it IS the “fallback” state.
  • Power Safe Range: You can set an acceptable range for power usage. If the power consumption goes beyond this range, you will receive a notification if you opt to do so.
    WARNING: This option is NOT available if the “Output Device” is assigned to an outlet that cannot monitor power, such as a WiFi Strip outlet.
  • Power Notification Level: You can select the notification level that triggers if the power consumption falls outside the “Power Safe Range.”
    WARNING: This option is NOT available if the “Output Device” is assigned to an outlet that cannot monitor power, such as a WiFi Strip outlet.
  • Active Modes: This allows you to choose which modes this output will be active and in which modes the output should turn OFF
  • Depends On: This feature allows you to turn the output based on the status of another output. To enable, select from the list of available outputs.  
    • Dependency Mode: You can turn the output ON or OFF based on the other output.
      • OFF if OFF: Will turn the current output OFF if the output it depends on is OFF.
      • OFF if ON: Will turn the current output OFF when the output it depends on is ON.
      • ON if OFF: Will turn the current output ON when the output it depends on is OFF.
      • ON if ON: Will turn the current output ON when the output it depends on is ON.
  • Is Invisible: If you choose to hide the input from the status screen, it will only become visible on pages that have “Show Invisible” selected.
  • Use Advanced Settings: If you are an expert, this feature will allow you to tweak the output default settings to suit your system better. See Appendix A below for more details.
EXAMPLE: Here is an example of a heater setup where the HYDROS is the primary controller, and the heater’s thermostat acts as backup:

Heater’s Integrated Thermostat Setup:

  • Set the heater’s integrated thermostat to 80 degrees.

HYDROS Controller Heater Output Setup:

  • ON Temperature: 78.0
  • OFF Temperature: 78.5

In this situation, the HYDROS controller is responsible for managing the heater on a daily basis. It will activate the heater outlet when the tank’s temperature falls below 78 degrees and switch it off when it reaches 78.5 degrees. If the HYDROS temperature sensor malfunctions and the heater remains on, the built-in thermostat will automatically deactivate it once the water temperature hits 80 degrees.

TIP: This setup also allows the HYDROS to monitor the power consumption of the outlet (if using a HYDROS-compatible device) and alert you when the heater is supposed to be on. Yet, HYDROS is not detecting any power draw on the outlet. This power monitoring feature is NOT possible if you use the integrated thermostat as the primary controller with the HYDROS as a backup.

Step 3: Save

  • Upload your changes to the cloud.

Appendix A: Advanced Settings

Control has a wide array of outputs and each output is preconfigured to fit the needs of more users.  From delaying the start of a skimmer to ensuring that a fluorescent bulb does not turn OFF immediately after turning ON, the control will already know how to handle individual devices.  If you are an Advanced User, then you probably will want to tweak the default settings to something that better fits your needs.  Here is where you would make those more advanced adjustments.

  • If Input Unavailable: This allows you to specify how the outlet should act if the sensor is not found or missing
  • Minimum OFF Time: Allows you to specify what is the minimum time the outlet should be OFF
  • Maximum OFF Time: Allows you to specify what is the maximum time the outlet should be OFF
  • Minimum ON Time: Allows you to specify what is the minimum time the outlet should be ON
  • Maximum ON Time: Allows you to specify what ist he maximum time the outlet should be ON
  • Run Past Max ON time: This allows you to specify if you want the outlet to remain ON even if the “Max ON Time” has been exceeded
  • Notification Level: Allows you to specify the level of notification you want when any of the advanced settings have been exceeded
TIP: You will get notifications any time one or more of the advanced settings have been exceeded.  If you set Notification Level to NONE, then the particular outlet you configured will not send you any notifications.

Rename Output & Change Icon

  • From the STATUS screen, tap on the Output you wish to modify.
  • On the popup, tap on the “Gear” icon on the bottom right.
  • From the Output setup page, tap on the “Pencil” icon on the top left.
  • Type in the new name you wish
  • If you wish to change the default icon, tap “Change Icon.”