Add “Sampled” Salinity Input

Do you know what “Sampled Salinity” means? With HYDROS, you can now test Salinity more safely and accurately. By placing the Conductivity probe in the HYDROS iV, the Conductivity probe is located in a fully isolated vessel, ensuring stray voltage from equipment like pumps or heaters won’t compromise the readings. 

TIP: When configuring your iV Tester Output [1], this input is automatically generated and added to your status screen. If you need to recreate it manually, follow the instructions below.

Before Creating the Sampled Salinity Input…

  1. Ensure you have a fully configured iV Output [1].
  2. Select a Salinity Input at the bottom of the iV Output [1] configuration page

Now, we can manually create the input.

Step 1: Create the Sampled Salinity Input

  1. From the STATUS screen, tap the three horizontal dots to the right of the INPUTS label.
  2. Select “Add/Edit Input”
  3. Tap on the + symbol in the bottom-right corner
  4. Enter the name you wish to assign to your input and tap “Create.”

Step 2: Configure the Sampled Salinity Input

Step 3: Upload the changes

  1. Once you upload the changes, the status screen automatically displays a new “Sampled Salinity” input.

Calibrate/Offset Reading

If you notice an inaccurate Sampled Salinity reading, you can go to the Conductivity/Salinity Probe Input [2] setup page and recalibrate or apply an offset there.

Rename Input & Change Icon

  • From the STATUS screen, tap on the Input you wish to modify.
  • On the popup, tap on the “Gear” icon on the bottom right.
  • From the Input setup page, tap on the “Pencil” icon on the top left.
  • Type in the new name you wish
  • If you wish to change the default icon, please tap on “Change Icon.”