The HYDROS system is designed to work seamlessly with 12V backup batteries. It can detect when it’s running on battery power and automatically switch to a “Low Power” mode as specified by the user. With this mode, you can select which outputs and schedules should continue running and which should stop completely.

What you need to get started

Step 1: Create Low Power Mode

Add a new Mode [2] and configure it using the following values:

Step 2: Assign Low Power Mode

From the Main Menu, select OPTIONS

Step 3: Test Your Setup

It is important not to assume that everything is working perfectly. To ensure your settings are correct, you should test them by simulating a power outage. You can do this by shutting off the circuit breaker or unplugging all devices from the power source. Please take note of how your tank and equipment react when everything is turned off, and observe how they respond as everything is powered back on. Make any necessary adjustments and repeat the testing process until satisfied with the results.

EXAMPLE:

Create Low Power Schedule (Flow Pumps)

If you own a WaveEngine or one that operates as part of a group, chances are you have flow pumps running. You can create a distinct Flow Schedule that operates only in “Low Power” mode. This schedule would only run specific pumps at a designated velocity.

Create a new Schedule and configure it using the following values:

  • Pattern – Constant Speed – Constant speed is the most power-efficient flow.  Ramping the pump up/down will consume more battery power.
  • Constant Speed – Set this to 1% if you want the pumps to run at Minimum Speed.  Depending on your system, you might have to play and test different speeds until you find one that fits your needs.  You want water to move around, but it is unnecessary to “whip” the corals when running on battery power.  
  • Pump Count – Set this to the number of pumps you want to run when this schedule is active.  
    WARNING: The battery will be depleted faster if you run more pumps simultaneously.
  • Pump # – Select each pump you want to add to the schedule.
  • Position # – Select the position you want this pump to assume when running in this schedule.  
  • Allow Reverse – Do Not Enable
  • Start Time –  Set this to 00:00:00
  • End Time – Set this to 00:00:00
  • Run every N Days – Set this to 1
  • Run On Days of Week – Select ALL days of the week
  • Depends On – Unused
  • Enable Advanced Settings – Leave them disabled.